A range of options to meet your needs.

Our L-Series range of arc proof panels are available in two distinct primary configurations, as well as an ATS option:

The L-Series MVE Panel System

Voltage 2.3 - 13.8 kV 
Amps < 540 A (standard)
< 1200 A (to order) 
Loss of service continuity LSC1 (E1 & E2 config.)
LSC2/LSC2B (E3 config.) 
Rated short time withstand current/peak Up to 40 kA for 1 sec/104 kA 
Internal arc fault classification AFL 31.5 kA for 1 sec 
Installation configuration Standalone or line-up 

The MVE soft starter is a powerful and reliable solution for your medium voltage starting requirements. Extensive personal safety features, an easy-to-use graphical interface, and comprehensive built-in motor/load protection make this a well balanced solution for your medium voltage needs.

Read more...

L-Series MVX Panel System

Voltage 11 kV 
Amps < 450 A
Loss of service continuity LSC2B
Rated short time withstand current/peak Up to 31.5 kA for 4 sec/82 kA
(or up to  40 kA for 3 sec)
Internal arc fault classification AFLR 31.5 kA for 1 sec 
Installation configuration Standalone or line-up 

The L-Series MVX soft starter is the smallest medium voltage soft-starter in its class, with a smaller panel footprint than any other MV soft starter in the market today.

The L-Series MVX panel system is a complete switchgear solution and features a withdrawable (rack in/out) main device and soft starter power assembly.

Additional advanced features including PM class partitioning, an LSC2B design and a rated short time withstand current of up to 31.5 kA for 4 seconds (or 40 kA for 3 seconds) set the L-Series MVX apart as a clear market leader.

Read more...

The L-Series ATS Panel System

Voltage 2.3 - 13.8 kV 
Amps < 540 A (standard)
< 1200 A (to order) 
Loss of service continuity LSC1 (E1 & E2 config.)
LSC2/LSC2B (E3 config.) 
Rated short time withstand current/peak Up to 40 kA for 1 sec/104 kA 
Internal arc fault classification AFL 40 kA for 1 sec 
Installation configuration Standalone or line-up 

The ATS starter is a powerful and reliable solution for your medium voltage starting requirements. Extensive personal safety features, an easy-to-use graphical interface, and comprehensive built-in motor/load protection make this a well balanced solution for your medium voltage needs.
Read more...

The L-Series MVE: Key details

Voltage 2.3 - 13.8 kV 
Amps < 540 A (standard)
< 1200 A (to order) 
Loss of service continuity LSC1 (E1 & E2 config.)
LSC2/LSC2B (E3 config.) 
Rated short time withstand current/peak Up to 40 kA for 1 sec/104 kA 
Internal arc fault classification AFL 31.5 kA for 1 sec 
Installation configuration Standalone or line-up 

 

Meet the L-Series MVE Panel System.

The L-Series panel system is the realisation of a vision that many claimed was impossible. From inception, flexibility has been the primary focus of the L-Series design.

Now, our decades of experience and expertise in design, engineering, manufacturing and after sales service has culminated in the development of this new AuCom global switchgear standard.

The L-Series is the most universal switchgear system on the market today.

Fully type tested.

AuCom L-Series panels are fully type tested according to IEC 62271-200:

Short time withstand current
Peak withstand current
Internal arc fault (IAC classification: AFL 31.5 kA for 1 second)
Dielectric test on main and auxiliary circuits
IP rating
Temperature rise test related to 50 °C ambient temperature and main circuit resistance
Certificates are available from AuCom on request.

Arc fault protection.

If an arc event occurs within an AuCom L-Series panel, the arc fault is contained by solid locking doors and heavy double layer compartment panels.

During the emission phase, the pressure is safely released using discharge flaps on the top of the panel (or optional ducts), which direct the explosion upwards or vent it safely outside.

Panel details:

L-Series MVE panels are available in either IP4X or IP54 panels, with options for line and bypass devices, earthing and isolation switches. AuCom can also design and build panels to meet particular specifications, and we offer full application engineering support at all stages of the design process.

In addition to standard packages we can supply a complete line up to meet your requirements, including the following options:

  • Top or bottom cable input (motor & control wires)
  • Supply voltage: top, bottom or main busbar system
  • Switching devices (line & bypass): vacuum contactor or circuit breaker
  • Internal power factor correction with capacitor, vacuum contactor, fuses and inrush current limiter
  • Control voltage source: internal via MV control transformer or external via customer terminal blocks
  • Earthing/Disconnector: Input, output or main busbar system

The L-Series MVX: Key details

Voltage 11 kV 
Amps < 450 A
Loss of service continuity LSC2B
Rated short time withstand current/peak Up to 31.5 kA for 4 sec/82 kA
(or up to  40 kA for 3 sec)
Internal arc fault classification AFLR 31.5 kA for 1 sec 
Installation configuration Standalone or line-up 

The smallest soft starter in the world.

The L-Series MVX soft starter is the smallest medium voltage soft-starter in its class, with a smaller panel footprint than any other MV soft starter in the market today. Space is a big advantage in lowering your switchroom costs and provides more flexibility where space is needed like marine applications.

Current range: Up to 450 A
Motor connection: Inline
Rated voltage class: Up to 15 kV
Mains frequency: 45 Hz to 66 Hz

The safest soft starter in the world.

To ensure your staff and plant are safe from arc fault, AuCom L-Series panels are the only choice. The L-Series panel system meets or exceeds all the relevant IEC standards for internal arc fault resistance. L-series MVX panels can even withstand an arc event in one compartment without affecting neighbouring compartments. Type tested panels meet Internal arc classification (IAC) AFLR to a maximum of 31.5 kA for 1 second.

Easier to service.

AuCom has eliminated complex disassembly to replace or service a part. The L-series MVX panels are designed with easy rack-in, rack-out operation. Components can be inspected through viewing windows and are easily accessible via hinged doors or removable panels, while still keeping unauthorised people out.

More flexibility.

Don't feel constrained in the choice of apparatus in your switchgear, AuCom panels are compatible with all of the major apparatus suppliers.

The L-Series MVX soft starter is available in a range of configurations up to rated voltage class 15 kVA and 450 A. AuCom has a full service capability to design and manufacture your entire Motor Control Centre.

The L-Series ATS: Key details

Voltage 2.3 - 13.8 kV 
Amps < 540 A (standard)
< 1200 A (to order) 
Loss of service continuity LSC1 (E1 & E2 config.)
LSC2/LSC2B (E3 config.) 
Rated short time withstand current/peak Up to 40 kA for 1 sec/104 kA 
Internal arc fault classification AFL 40 kA for 1 sec 
Installation configuration Standalone or line-up 

 

Meet the L-Series ATS Panel System.

The L-Series panel system is the realisation of a vision that many claimed was impossible. From inception, flexibility has been the primary focus of the L-Series design.

Now, our decades of experience and expertise in design, engineering, manufacturing and after sales service has culminated in the development of this new AuCom global switchgear standard.

The L-Series is the most universal switchgear system on the market today.

Panel details:

L-Series ATS panels are available in either IP4X or IP54 panels, with options for line and bypass devices, earthing and isolation switches. AuCom can also design and build panels to meet particular specifications, and we offer full application engineering support at all stages of the design process.

In addition to standard packages we can supply a complete line up to meet your requirements, including the following options:

  • Top or bottom cable input (motor & control wires)
  • Supply voltage: top, bottom or main busbar system
  • Switching devices (line & bypass): vacuum contactor or circuit breaker
  • Internal power factor correction with capacitor, vacuum contactor, fuses and inrush current limiter
  • Control voltage source: internal via MV control transformer or external via customer terminal blocks
  • Earthing/Disconnector: Input, output or main busbar system